Broseley eVolution 4 Spezifikationen Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
eVo5MS0711 08/07/2011
TroubleShooting
1. Smokecomesoutofthestovewhentheloadingdoorisopened.
Thechimneycavityintowhichthe125mmfluepipehasbeeninstalledmaybelessthan
theminimumrequirement.
Deposits(soot)mayhavebuiltupinthechimneyandberestrictingtheflowofwaste
products.Thisflowrateisknownasthe‘draw’.
2. TheStovedoesnotproducetheexpectedheatintotheroom.
Hasthefluepipebeense aledtothechimneytopreventheatbeingdrawnupthe
chimneytowaste?
Greenorwetwoodisbeingburnt.
Thechimneyhasexcessivedraw(thisisunusual).Seekinstalleradvicewithregard
toinstallingaFlueDraughtStabiliser.
Thestovehasbeenrecessedintotheexistingfireplaceandalotofheatisabsorbed
bethesurroundingfireplacewallsratherthanbeingradiatedintotheroom.Pullthe
stoveforward.
Forthemaximumefficiencyofheattransferenceintotheroomthestoveshouldbe
sitedonthehearthofthefireplaceratherthanrecessed.
3. TheStoveburnstoofast.
Usewholelogsratherthansplitones.
Thewoodbeingusedmaybegenerally
toosmall.
The“airtight”sealbetweenthefibreropeonthe doorsandthecastingmayhavebeen
lost,adjustdoorhandlelocknutstoreinstatethisseal.
Thechimneyhasexcessivedraw(seekinstallersadviceonthispoint).
Thefibreropesealbetweenthedoorand
theglassmaybeleaking.Tightenorreplace.
Theglassisnotsealed,gentlytightenglassretainingclips.Donotovertightenasthiswill
stressorbreaktheglass.
Thefibreropeondoorsandglasshaswornout.Replace.
4. TheCastingsdonot
lineup
Thereareseveralpositionsonthesidecastingstoallowadjustmentifthecastingsdo
notlineupcorrectly.Byusingsmallrotationsadjustthescrewsattachedtothesideto
suitthedesireddistanceneeded.
Ensurethebaseisattachedcorrectlyandorlinesuptothesidecastingsbefore
tighteningfully.
Seitenansicht 19